Automated Organization ProfileB.S.N. Srl R&D Laboratory, Castelleone (Italy)
B.S.N. Srl R&D Laboratory, Castelleone (Italy)
Current S-Index
Sum of Dataset Indices for all datasets
Average Dataset Index per Dataset
Average Dataset Index per dataset
Total Datasets
Total datasets in this organization
Average FAIR Score
Average FAIR Score per dataset
Total Citations
Total citations to the organization's datasets
Total Mentions
Total mentions of the organization's datasets
S-Index Interpretation
The S-Index (Sharing Index) is a comprehensive metric that represents the cumulative impact of all your datasets. It is calculated as the sum of Dataset Index scores across all your claimed datasets.
What it means:
- A higher S-index indicates greater overall impact of your datasets relative to typical datasets in their fields of research
- The S-Index grows as you add more datasets or as existing datasets gain more citations and mentions
- It provides a single number to track your research data impact over time
Current S-Index: 2.3 (sum of 2 datasets Dataset Index scores)
More information here.
S-Index Over Time
Cumulative Citations Over Time
Cumulative Mentions Over Time
Datasets
This database includes the raw data linked with the paper “On-line Solid Phase Extraction High Performance Liquid Chromatography Method Coupled with Tandem Mass Spectrometry for the Therapeutic Monitoring of Cannabidiol and 7-Hydroxy-cannabidiol in Human Serum and Saliva". Cannabidiol is a novel antiseizure medication approved in Europe and the US for the treatment of seizures associated with Lennox-Gastaut syndrome, Dravet syndrome and tuberous sclerosis complex. We describe in this article a new and simple liquid chromatography-mass spectrometry method (LC-MS/MS) for the determination of cannabidiol and its active metabolite 7-hydroxy-cannabidiol in microvolumes of serum and saliva (50 μL), to be used as a tool for therapeutic drug monitoring (TDM) and pharmacokinetic studies. After on-line solid phase extraction cannabidiol, 7-hydroxy-cannabidiol and the internal standard cannabidiol-d3 are separated on a monolithic C18 column under gradient conditions. Calibration curves are linear within the validated concentration range (10-1000 ng/mL for cannabidiol and 5-500 ng/mL for 7-hydroxy-cannabidiol). The method is accurate (intraday and interday accuracy within 94-112% for cannabidiol, 91-109% for 7-hydroxy-cannabidiol), precise (intraday and interday precision <11.6% for cannabidiol and <11.7% for 7- hydroxy-cannabidiol) and sensitive, with a LOQ of 2.5 ng/mL for cannabidiol and 5 ng/mL for 7-hydroxy-cannabidiol. The stability of the analytes was confirmed under different storage conditions. Extraction recoveries were in the range of 81-129% for cannabidiol and 100-113% for 7-hydroxy-cannabidiol. The applicability of the method to TDM was demonstrated by analysis of human serum and saliva samples obtained from patients with epilepsy treated with cannabidiol.
Authors
- Valentina, Franco ;
- Palmisani Michela ;
- Marchiselli Roberto ;
- Crema Francesca ;
- Fattore Cinzia ;
- De Giorgis Valentina, ;
- Costanza, Varesio ;
- Paola, Rota ;
- Dibari Vincenza Flora ;
- Perucca Emilio
This database includes the raw data linked with the paper “On-line Solid Phase Extraction High Performance Liquid Chromatography Method Coupled with Tandem Mass Spectrometry for the Therapeutic Monitoring of Cannabidiol and 7-Hydroxy-cannabidiol in Human Serum and Saliva". Cannabidiol is a novel antiseizure medication approved in Europe and the US for the treatment of seizures associated with Lennox-Gastaut syndrome, Dravet syndrome and tuberous sclerosis complex. We describe in this article a new and simple liquid chromatography-mass spectrometry method (LC-MS/MS) for the determination of cannabidiol and its active metabolite 7-hydroxy-cannabidiol in microvolumes of serum and saliva (50 μL), to be used as a tool for therapeutic drug monitoring (TDM) and pharmacokinetic studies. After on-line solid phase extraction cannabidiol, 7-hydroxy-cannabidiol and the internal standard cannabidiol-d3 are separated on a monolithic C18 column under gradient conditions. Calibration curves are linear within the validated concentration range (10-1000 ng/mL for cannabidiol and 5-500 ng/mL for 7-hydroxy-cannabidiol). The method is accurate (intraday and interday accuracy within 94-112% for cannabidiol, 91-109% for 7-hydroxy-cannabidiol), precise (intraday and interday precision <11.6% for cannabidiol and <11.7% for 7- hydroxy-cannabidiol) and sensitive, with a LOQ of 2.5 ng/mL for cannabidiol and 5 ng/mL for 7-hydroxy-cannabidiol. The stability of the analytes was confirmed under different storage conditions. Extraction recoveries were in the range of 81-129% for cannabidiol and 100-113% for 7-hydroxy-cannabidiol. The applicability of the method to TDM was demonstrated by analysis of human serum and saliva samples obtained from patients with epilepsy treated with cannabidiol.
Authors
- Valentina, Franco ;
- Palmisani Michela ;
- Marchiselli Roberto ;
- Crema Francesca ;
- Fattore Cinzia ;
- De Giorgis Valentina, ;
- Costanza, Varesio ;
- Paola, Rota ;
- Dibari Vincenza Flora ;
- Perucca Emilio