Automated Organization ProfileCSIRO Energy, Australia
CSIRO Energy, Australia
Current S-Index
Sum of Dataset Indices for all datasets
Average Dataset Index per Dataset
Average Dataset Index per dataset
Total Datasets
Total datasets in this organization
Average FAIR Score
Average FAIR Score per dataset
Total Citations
Total citations to the organization's datasets
Total Mentions
Total mentions of the organization's datasets
S-Index Interpretation
The S-Index (Sharing Index) is a comprehensive metric that represents the cumulative impact of all your datasets. It is calculated as the sum of Dataset Index scores across all your claimed datasets.
What it means:
- A higher S-index indicates greater overall impact of your datasets relative to typical datasets in their fields of research
- The S-Index grows as you add more datasets or as existing datasets gain more citations and mentions
- It provides a single number to track your research data impact over time
Current S-Index: 8.2 (sum of 2 datasets Dataset Index scores)
More information here.
S-Index Over Time
Cumulative Citations Over Time
Cumulative Mentions Over Time
Datasets
This dataset consists of multi-resolution X-Ray micro-tomography images of two Bentheimer sandstone rock cores. The rock cores were first used experimentally in [1] with further modelling in [2]. This new dataset is used directly in the publication [3] - preprint available at https://arxiv.org/abs/2111.01270. The original dataset from [1] (of the same rock cores) is hosted on the BGS National Geoscience Data Centre, ID #130625 at dx.doi.org/10.5285/5f899de8-4085-4370-a45e-e613f27e8f1d and there is also a subvolume image dataset, for easier download available on the Digital Rocks Portal, project 229, DOI:10.17612/KT0B-SZ28 at digitalrocksportal.org/projects/229. The images provided herein are from two distinct Bentheimer rock cores -- core 1 and core 2. The cores have diameter, 12.35mm, lengths 73.2mm and 64.7mm, core-averaged porosities of 0.203 and 0.223 and permeabilities of 1.636D and 0.681D for core 1 and 2, respectively. Core 2 has a clear low permeability lamination occurring at 2/3 of the total core length, whereas core 1 has a general fining towards the outlet of the core creating a reduction in porosity [1]. The images were acquired with a Zeiss Versa 510 X-Ray CT scanner. We acquired images of two sub volumes from each core, at locations 1/3rd (subvolume 1) and 2/3rds (subvolume 2) of the way along the core length, at resolutions of 2, 6 and 18 microns. We refer to the 2 micron images as high-resolution (HR), the 6 micron images as low-resolution (LR) and the 18 micron images as very-low-resolution (VLR). There are also super-resolution (SR) images created at 2 micron resolution from the LR images, using a deep-learning algorithm. There are also cubic interpolation images created from the LR image - these are labels bicubic. These have a resolution of 2 microns, and size equal to the HR and SR images. Details of the SR and LR Bicubic generation are found in [3]. The following scanning protocols were used for the direct imaging: 2 micron images:
--We use a 4x microscope objective, an exposure time of 8s, 2x averaged binning, 9001 projections, a scan voltage of 80kV and a power of 7W. Each scan takes approximately 24 hours. 6 micron images:
--We use a flat panel detector, an exposure time of 0.7s, 10x repeat frames, 1x averaged binning, 2401 projections, a scan voltage of 80kV and a power of 7W. The cone angle is 14.46 degrees and the fan angle is 22.2 degrees. Each scan takes approximately 1 hour. 18 micron images:
--We use a 0.4x microscope objective, an exposure time of 1s, 10x repeat frames, 1x averaged binning, 2401 projections, a scan voltage of 80kV and a power of 7W. The cone angle is 12.65 degrees and the fan angle is 12.65 degrees. Each scan takes approximately 2 hours. We present 4 sets of the images with different levels of processing. All images are mutual registered to each other. Each image filename has a Core#_Subvol#_resolution identifier, either with the actual resolution (e.g. 6) or the short form (e.g. LR). The following name endings are used (1) - '_16bit_LE.raw'. These are the .raw images of little-endian format. Preceding this filename is also the cubic image side length in voxels, e.g. _75cube. 12 images in total. (2) - '_16bit_LE_normalised.raw'. These are the .raw images of little-endian format with normalised greyscale values following the procedure in [1]. Preceding this filename is also the cubic image side length in voxels, e.g. _75cube. 12 images in total. (3) - 'Core1_Subvol1_HR' etc. These are the .tiff images of (2) above, which have been converted to 8 bit. Includes bicubic interpolation images and SR images, but no 16 micron images, since these were not used in the analysis of [3]. 16 images in total. (4) - 'Core1_Subvol1_HR_filtered' etc. These are the .tiff images from (3) above, which have filtered using non-local means filtering. More details are found in [3]. Note there are no SR images here since they are already essentially filtered, and included in (3) above. 12 images in total.
References
[1] Jackson, S.J., Lin, Q. and Krevor, S. 2020. Representative Elementary Volumes, Hysteresis, and Heterogeneity in Multiphase Flow from the Pore to Continuum Scale. Water Resources Research, 56(6), e2019WR026396 [2] Zahasky, C., Jackson, S.J., Lin, Q., and Krevor, S. 2020. Pore network model predictions of Darcy‐scale multiphase flow heterogeneity validated by experiments. Water Resources Research, 56(6), e e2019WR026708. [3] Jackson, S.J, Niu, Y., Manoorkar, S., Mostaghimi, P. and Armstrong, R.T. 2021. Deep learning of multi-resolution X-Ray micro-CT images for multi-scale modelling. Under review, preprint available at https://arxiv.org/abs/2111.01270
Authors
- Jackson, Samuel J. ;
- Niu, Yufu ;
- Manoorkar, Sojwal ;
- Mostaghimi, Peyman ;
- Armstrong, Ryan
This dataset consists of multi-resolution X-Ray micro-tomography images of two Bentheimer sandstone rock cores. The rock cores were first used experimentally in [1] with further modelling in [2]. This new dataset is used directly in the publication [3] - preprint available at https://arxiv.org/abs/2111.01270. The original dataset from [1] (of the same rock cores) is hosted on the BGS National Geoscience Data Centre, ID #130625 at dx.doi.org/10.5285/5f899de8-4085-4370-a45e-e613f27e8f1d and there is also a subvolume image dataset, for easier download available on the Digital Rocks Portal, project 229, DOI:10.17612/KT0B-SZ28 at digitalrocksportal.org/projects/229. The images provided herein are from two distinct Bentheimer rock cores -- core 1 and core 2. The cores have diameter, 12.35mm, lengths 73.2mm and 64.7mm, core-averaged porosities of 0.203 and 0.223 and permeabilities of 1.636D and 0.681D for core 1 and 2, respectively. Core 2 has a clear low permeability lamination occurring at 2/3 of the total core length, whereas core 1 has a general fining towards the outlet of the core creating a reduction in porosity [1]. The images were acquired with a Zeiss Versa 510 X-Ray CT scanner. We acquired images of two sub volumes from each core, at locations 1/3rd (subvolume 1) and 2/3rds (subvolume 2) of the way along the core length, at resolutions of 2, 6 and 18 microns. We refer to the 2 micron images as high-resolution (HR), the 6 micron images as low-resolution (LR) and the 18 micron images as very-low-resolution (VLR). There are also super-resolution (SR) images created at 2 micron resolution from the LR images, using a deep-learning algorithm. There are also cubic interpolation images created from the LR image - these are labels bicubic. These have a resolution of 2 microns, and size equal to the HR and SR images. Details of the SR and LR Bicubic generation are found in [3]. The following scanning protocols were used for the direct imaging: 2 micron images:
--We use a 4x microscope objective, an exposure time of 8s, 2x averaged binning, 9001 projections, a scan voltage of 80kV and a power of 7W. Each scan takes approximately 24 hours. 6 micron images:
--We use a flat panel detector, an exposure time of 0.7s, 10x repeat frames, 1x averaged binning, 2401 projections, a scan voltage of 80kV and a power of 7W. The cone angle is 14.46 degrees and the fan angle is 22.2 degrees. Each scan takes approximately 1 hour. 18 micron images:
--We use a 0.4x microscope objective, an exposure time of 1s, 10x repeat frames, 1x averaged binning, 2401 projections, a scan voltage of 80kV and a power of 7W. The cone angle is 12.65 degrees and the fan angle is 12.65 degrees. Each scan takes approximately 2 hours. We present 4 sets of the images with different levels of processing. All images are mutual registered to each other. Each image filename has a Core#_Subvol#_resolution identifier, either with the actual resolution (e.g. 6) or the short form (e.g. LR). The following name endings are used (1) - '_16bit_LE.raw'. These are the .raw images of little-endian format. Preceding this filename is also the cubic image side length in voxels, e.g. _75cube. 12 images in total. (2) - '_16bit_LE_normalised.raw'. These are the .raw images of little-endian format with normalised greyscale values following the procedure in [1]. Preceding this filename is also the cubic image side length in voxels, e.g. _75cube. 12 images in total. (3) - 'Core1_Subvol1_HR' etc. These are the .tiff images of (2) above, which have been converted to 8 bit. Includes bicubic interpolation images and SR images, but no 16 micron images, since these were not used in the analysis of [3]. 16 images in total. (4) - 'Core1_Subvol1_HR_filtered' etc. These are the .tiff images from (3) above, which have filtered using non-local means filtering. More details are found in [3]. Note there are no SR images here since they are already essentially filtered, and included in (3) above. 12 images in total.
References
[1] Jackson, S.J., Lin, Q. and Krevor, S. 2020. Representative Elementary Volumes, Hysteresis, and Heterogeneity in Multiphase Flow from the Pore to Continuum Scale. Water Resources Research, 56(6), e2019WR026396 [2] Zahasky, C., Jackson, S.J., Lin, Q., and Krevor, S. 2020. Pore network model predictions of Darcy‐scale multiphase flow heterogeneity validated by experiments. Water Resources Research, 56(6), e e2019WR026708. [3] Jackson, S.J, Niu, Y., Manoorkar, S., Mostaghimi, P. and Armstrong, R.T. 2021. Deep learning of multi-resolution X-Ray micro-CT images for multi-scale modelling. Under review, preprint available at https://arxiv.org/abs/2111.01270