Automated Author ProfileSteuernagle IV, J.H.
Steuernagle IV, J.H.
Current S-Index
Sum of Dataset Indices for all datasets
Average Dataset Index per Dataset
Average Dataset Index per dataset
Total Datasets
Total datasets for this author
Average FAIR Score
Average FAIR Score per dataset
Total Citations
Total citations to the author's datasets
Total Mentions
Total mentions of the author's datasets
S-Index Interpretation
The S-Index (Sharing Index) is a comprehensive metric that represents the cumulative impact of all your datasets. It is calculated as the sum of Dataset Index scores across all your claimed datasets.
What it means:
- A higher S-index indicates greater overall impact of your datasets relative to typical datasets in their fields of research
- The S-Index grows as you add more datasets or as existing datasets gain more citations and mentions
- It provides a single number to track your research data impact over time
Current S-Index: 1.1 (sum of 2 datasets Dataset Index scores)
More information here.
S-Index Over Time
Cumulative Citations Over Time
Cumulative Mentions Over Time
Datasets
Background: Acute metabolic acidosis is rarely associated with a reduced or negative anion gap (AG), but several case reports have described such an abnormality occurring in the setting of acute salicylate intoxication. The underlying cause of this phenomenon is unclear. Methods: In this retrospective cohort study, we reviewed our institutional database to identify all patients admitted for salicylate intoxication at Mayo Clinic (Rochester, MN, USA) from January 2010 through December 2012. Serum chloride was measured with the Cobas INTEGRA 400 plus electrode (expedited laboratory test) or Cobas 6000 (routine laboratory test). We compared blood chloride levels measured by the 2 devices in the presence of positive blood salicylate level. Results: Twelve adult patients with salicylate levels >20 mg/dL had markedly elevated chloride concentrations. The median (interquartile range) chloride level at admission was 120 (107–145) mmol/L on their initial laboratory studies, resulting in reduced or even negative AGs. None of the patients had bromide toxicity, nor did they have any other identifiable cause of hyperchloremia or decreased AG. Further testing of the same blood samples with an alternative measurement system (Roche Cobas 6000) yielded normal chloride values, indicating that falsely elevated chloride values with the initial testing led to the diminished or negative AG values. Conclusion: Circulating levels of salicylate can interfere with chloride measured by using routine techniques, resulting in spurious hyperchloremia outcomes and erroneous AG values. In patients with acute metabolic acidosis and abnormally reduced or negative AG, salicylate interference with chloride measurement should be suspected.
Authors
- Kashani, K.B. ;
- Steuernagle IV, J.H. ;
- Qian, Q.
Background: Acute metabolic acidosis is rarely associated with a reduced or negative anion gap (AG), but several case reports have described such an abnormality occurring in the setting of acute salicylate intoxication. The underlying cause of this phenomenon is unclear. Methods: In this retrospective cohort study, we reviewed our institutional database to identify all patients admitted for salicylate intoxication at Mayo Clinic (Rochester, MN, USA) from January 2010 through December 2012. Serum chloride was measured with the Cobas INTEGRA 400 plus electrode (expedited laboratory test) or Cobas 6000 (routine laboratory test). We compared blood chloride levels measured by the 2 devices in the presence of positive blood salicylate level. Results: Twelve adult patients with salicylate levels >20 mg/dL had markedly elevated chloride concentrations. The median (interquartile range) chloride level at admission was 120 (107–145) mmol/L on their initial laboratory studies, resulting in reduced or even negative AGs. None of the patients had bromide toxicity, nor did they have any other identifiable cause of hyperchloremia or decreased AG. Further testing of the same blood samples with an alternative measurement system (Roche Cobas 6000) yielded normal chloride values, indicating that falsely elevated chloride values with the initial testing led to the diminished or negative AG values. Conclusion: Circulating levels of salicylate can interfere with chloride measured by using routine techniques, resulting in spurious hyperchloremia outcomes and erroneous AG values. In patients with acute metabolic acidosis and abnormally reduced or negative AG, salicylate interference with chloride measurement should be suspected.
Authors
- Kashani, K.B. ;
- Steuernagle IV, J.H. ;
- Qian, Q.