Automated Author ProfileJuneja, Achint
Juneja, Achint
Current S-Index
Sum of Dataset Indices for all datasets
Average Dataset Index per Dataset
Average Dataset Index per dataset
Total Datasets
Total datasets for this author
Average FAIR Score
Average FAIR Score per dataset
Total Citations
Total citations to the author's datasets
Total Mentions
Total mentions of the author's datasets
S-Index Interpretation
The S-Index (Sharing Index) is a comprehensive metric that represents the cumulative impact of all your datasets. It is calculated as the sum of Dataset Index scores across all your claimed datasets.
What it means:
- A higher S-index indicates greater overall impact of your datasets relative to typical datasets in their fields of research
- The S-Index grows as you add more datasets or as existing datasets gain more citations and mentions
- It provides a single number to track your research data impact over time
Current S-Index: 1.3 (sum of 2 datasets Dataset Index scores)
More information here.
S-Index Over Time
Cumulative Citations Over Time
Cumulative Mentions Over Time
Datasets
ABSTRACT Introduction: Proximal stripping of enamel is a routine clinical procedure employed in orthodontics to create space or for balancing tooth size discrepancies. This procedure may result in heat transfer to the pulp, predisposing it to histopathological changes and necrosis of the pulp tissue. Objective: To measure the temperature changes in the pulp chamber during different stripping procedures. Methods: 80 proximal surfaces of 40 extracted human premolar teeth were stripped using four techniques: diamond burs in air-rotor handpiece with air-water spray; diamond burs in micromotor handpiece, with and without a coolant spray; and hand-held diamond strips. A J-type thermocouple connected to a digital thermometer was inserted into the pulp chamber for evaluation of temperature during the stripping procedure. Results: An increase in the pulpal temperature was observed for all stripping method. Diamond burs in micromotor handpiece without coolant resulted in the higher increase in temperature (3.5oC), followed by hand-held diamond strips (2.8oC), diamond burs in air-rotor with air-water spray (1.9oC); and the smallest increase was seen with diamond burs in micromotor handpiece with coolant (1.65oC). None of the techniques resulted in temperature increase above the critical level of 5.5oC. Conclusion: Frictional heat produced with different stripping techniques results in increase in the pulpal temperature, therefore, caution is advised during this procedure. A coolant spray can limit the increase in temperature of the pulp.
Authors
- Sehgal, Megha ;
- Sharma, Payal ;
- Juneja, Achint ;
- Kumar, Piush ;
- Verma, Anubha ;
- Chauhan, Vikas
ABSTRACT Introduction: Proximal stripping of enamel is a routine clinical procedure employed in orthodontics to create space or for balancing tooth size discrepancies. This procedure may result in heat transfer to the pulp, predisposing it to histopathological changes and necrosis of the pulp tissue. Objective: To measure the temperature changes in the pulp chamber during different stripping procedures. Methods: 80 proximal surfaces of 40 extracted human premolar teeth were stripped using four techniques: diamond burs in air-rotor handpiece with air-water spray; diamond burs in micromotor handpiece, with and without a coolant spray; and hand-held diamond strips. A J-type thermocouple connected to a digital thermometer was inserted into the pulp chamber for evaluation of temperature during the stripping procedure. Results: An increase in the pulpal temperature was observed for all stripping method. Diamond burs in micromotor handpiece without coolant resulted in the higher increase in temperature (3.5oC), followed by hand-held diamond strips (2.8oC), diamond burs in air-rotor with air-water spray (1.9oC); and the smallest increase was seen with diamond burs in micromotor handpiece with coolant (1.65oC). None of the techniques resulted in temperature increase above the critical level of 5.5oC. Conclusion: Frictional heat produced with different stripping techniques results in increase in the pulpal temperature, therefore, caution is advised during this procedure. A coolant spray can limit the increase in temperature of the pulp.
Authors
- Sehgal, Megha ;
- Sharma, Payal ;
- Juneja, Achint ;
- Kumar, Piush ;
- Verma, Anubha ;
- Chauhan, Vikas