Automated Author ProfileHelton F. Oliveira
Helton F. Oliveira
Current S-Index
Sum of Dataset Indices for all datasets
Average Dataset Index per Dataset
Average Dataset Index per dataset
Total Datasets
Total datasets for this author
Average FAIR Score
Average FAIR Score per dataset
Total Citations
Total citations to the author's datasets
Total Mentions
Total mentions of the author's datasets
S-Index Interpretation
The S-Index (Sharing Index) is a comprehensive metric that represents the cumulative impact of all your datasets. It is calculated as the sum of Dataset Index scores across all your claimed datasets.
What it means:
- A higher S-index indicates greater overall impact of your datasets relative to typical datasets in their fields of research
- The S-Index grows as you add more datasets or as existing datasets gain more citations and mentions
- It provides a single number to track your research data impact over time
Current S-Index: 0.9 (sum of 2 datasets Dataset Index scores)
More information here.
S-Index Over Time
Cumulative Citations Over Time
Cumulative Mentions Over Time
Datasets
This report describes a rapid and inexpensive colorimetric method based on biuret assay for total serum protein analysis using wax printed microzone plates and a desktop scanner. The colorimetric assay was performed in 96-microzone plates fabricated on polyester films through a wax printing protocol. The image scanning mode and the concentration of the biuret reagents were optimized to achieve the highest detectability levels. The best analytical response was obtained using the slide scanning mode as well as 4% CuSO4 and 150 mmol L-1 potassium sodium tartrate solutions. The proposed method offered linear relationship for the bovine serum albumin concentration range between 25 and 200 µmol L-1 with a limit of detection of 9.7 µmol L-1. The colorimetric approach revealed satisfactory precision (relative standard deviation values between 0.6 and 4.4%). The bioanalytical feasibility was demonstrated through the total protein analysis in serum samples collected from dogs previously diagnosed with kidney disease. The total serum protein concentrations varied from 960 ± 19 to 1661 ± 38 µmol L-1 and the achieved values revealed good accordance with those obtained through a reference method. Based on the reported results, wax printed microzone plates have demonstrated simplicity and potential to be adopted as alternative platforms for bioassays.
Authors
- Karoliny A. Oliveira ;
- Thiago M. G. Cardoso ;
- Helton F. Oliveira ;
- Fioravanti, Maria C. S. ;
- Coltro, Wendell K. T.
This report describes a rapid and inexpensive colorimetric method based on biuret assay for total serum protein analysis using wax printed microzone plates and a desktop scanner. The colorimetric assay was performed in 96-microzone plates fabricated on polyester films through a wax printing protocol. The image scanning mode and the concentration of the biuret reagents were optimized to achieve the highest detectability levels. The best analytical response was obtained using the slide scanning mode as well as 4% CuSO4 and 150 mmol L-1 potassium sodium tartrate solutions. The proposed method offered linear relationship for the bovine serum albumin concentration range between 25 and 200 µmol L-1 with a limit of detection of 9.7 µmol L-1. The colorimetric approach revealed satisfactory precision (relative standard deviation values between 0.6 and 4.4%). The bioanalytical feasibility was demonstrated through the total protein analysis in serum samples collected from dogs previously diagnosed with kidney disease. The total serum protein concentrations varied from 960 ± 19 to 1661 ± 38 µmol L-1 and the achieved values revealed good accordance with those obtained through a reference method. Based on the reported results, wax printed microzone plates have demonstrated simplicity and potential to be adopted as alternative platforms for bioassays.
Authors
- Karoliny A. Oliveira ;
- Thiago M. G. Cardoso ;
- Helton F. Oliveira ;
- Fioravanti, Maria C. S. ;
- Coltro, Wendell K. T.