Automated Author ProfileAllen, Lisa
University College London
Allen, Lisa
Current S-Index
Sum of Dataset Indices for all datasets
Average Dataset Index per Dataset
Average Dataset Index per dataset
Total Datasets
Total datasets for this author
Average FAIR Score
Average FAIR Score per dataset
Total Citations
Total citations to the author's datasets
Total Mentions
Total mentions of the author's datasets
S-Index Interpretation
The S-Index (Sharing Index) is a comprehensive metric that represents the cumulative impact of all your datasets. It is calculated as the sum of Dataset Index scores across all your claimed datasets.
What it means:
- A higher S-index indicates greater overall impact of your datasets relative to typical datasets in their fields of research
- The S-Index grows as you add more datasets or as existing datasets gain more citations and mentions
- It provides a single number to track your research data impact over time
Current S-Index: 1.0 (sum of 3 datasets Dataset Index scores)
More information here.
S-Index Over Time
Cumulative Citations Over Time
Cumulative Mentions Over Time
Datasets
.xlsx spreadsheets with ascii data recorded during reduction and reaction.
X-ray absorption spectroscopy was performed at Diamond Light Source, UK, at B18, through proposal SP30647 (August 2022) for the Pd/Al2O3, Pd/TiO2 and Pd/In2O3/Al2O3 species. Data was collected at the Pd and In K-edges in transmission mode using a QEXAFS setup with fast scanning Si(311) crystal monochromators. The time resolution here was roughly 90 seconds per spectrum. Samples were packed into an in-house custom-made capillary system designed and constructed by Diamond Light Source. 50 mg of 200-300 μm catalyst particles were packed between 3 cm of quartz wool.
DRIFTS measurements were performed on a Bruker VERTEX 80 system, with a custom-built high-pressure dome, capable of holding 25 bar of pressure within a high pressure chamber DiffusIRTM PIKE Technologies accessory. Argon and a 25% CO2/75% H2 mixture gas were delivered through high pressure EL-FLOW® Bronkhorst mass-flow controllers, into an in-house custom-made gas manifold. 30 mg of sample was used for the measurements. Initially, the sample was reduced in 25 mL/min of 25% H2 and 75 % Ar. The system was heated to 300 °C at a ramp rate of 5 °C/min and held for 1 hour. The samples were then cooled to 30 °C and either pressurised to 20 bar with 30 mL/min of 75% H2 and 25 % CO2 for the 20 bar measurements or kept at atmospheric pressure for the 1 bar measurements. Once the intended final pressure was reached, the system was heated at 10 °C/min, while holding at 50, 100, 150, 175, 200, 225, 250, 275 and 300 °C for 30 minutes for spectra to be collected. Mass-spectrometry data was collected throughout to observe the evolution of different species, using a Pfeiffer OmniStar.
Authors
- Beale, Andrew ;
- Potter, Matthew ;
- Allen, Lisa ;
- Vyas, Urvashi
X-ray absorption spectroscopy was performed at Diamond Light Source, UK, at B18 for the Pd/In2O3 & Pd/In2O3/Al2O3 species. Data was collected at the Pd and In K-edges in transmission mode using a QEXAFS setup with fast scanning Si(311) crystal monochromators. The time resolution here was roughly 90 seconds per spectrum. Samples were packed into an in-house custom-made capillary system designed and constructed by Diamond Light Source. 50 mg of 200-300 μm catalyst particles were packed between 3 cm of quartz wool.
Authors
- Beale, Andrew ;
- Allen, Lisa ;
- Negahdar, Leila
X-ray absorption spectroscopy was performed at Diamond Light Source, UK, at B18 for the Pd/In2O3 & Pd/In2O3/Al2O3 species. Data was collected at the Pd and In K-edges in transmission mode using a QEXAFS setup with fast scanning Si(311) crystal monochromators. The time resolution here was roughly 90 seconds per spectrum. Samples were packed into an in-house custom-made capillary system designed and constructed by Diamond Light Source. 50 mg of 200-300 μm catalyst particles were packed between 3 cm of quartz wool.
Authors
- Beale, Andrew ;
- Allen, Lisa ;
- Negahdar, Leila