Automated Author Profile

Muppavarapu, Venkatarao

Current S-Index

1.3

Sum of Dataset Indices for all datasets

Average Dataset Index per Dataset

0.6

Average Dataset Index per dataset

Total Datasets

2

Total datasets for this author

Average FAIR Score

13.5%

Average FAIR Score per dataset

Total Citations

2

Total citations to the author's datasets

Total Mentions

0

Total mentions of the author's datasets

S-Index Interpretation

S-Index Over Time

Cumulative Citations Over Time

Cumulative Mentions Over Time

Datasets

LC-ESI-MS/MS methods for the quantification of hydrazine mono lactose adduct and hydrazine di lactose adduct in isosorbide dinitrate and hydralazine hydrochloride tablets

Isosorbide dinitrate and hydralazine hydrochloride tablets treat heart failure in addition to conventional therapy, prolong hospitalization for heart failure, and enhance patient-reported functional status. LC-MS/MS methods developed and validated separately for the quantification of hydrazine mono-lactose adduct and hydrazine di-lactose adduct impurities in the isosorbide and hydralazine hydrochloride tablets. Separation of hydrazine mono-lactose adduct impurity achieved on ZIC-HILIC (100 × 4.6 mm, 5 µm) column with 0.1% formic acid in water as mobile phase A and acetonitrile as mobile phase B. The HPLC method gradient elution is; Tmin/% of B: 0/90, 15/40, 15.1/90, and 20/90. The flow rate is 1.0 mL per minute, and the injection volume is 20 µL. Separation of hydrazine di-lactose adduct impurity achieved on Inertsil HILIC (150 × 4.6 mm, 5 µm) column with 10 Mm ammonium acetate in water as mobile phase A and acetonitrile as mobile phase B. The HPLC method gradient elution is; Tmin/% of B: 0/90, 15/40, 15.1/90, and 18/90. The flow rate is 1.0 mL per minute, and the injection volume is 40 µL. Method validation has demonstrated both methods are specific, sensitive, linear, precise, accurate, stable and robust.

Authors

  • Muppavarapu, Venkatarao ;
  • Challa, Gangu Naidu ;
  • Gande, Mukteeshwar ;
  • Billa, Praveen Reddy ;
  • Yarraguntla, Srinivasa Rao
1 Citation0 Mentions13% FAIR0.6 Dataset Index
10.6084/m9.figshare.26318854January 2024

LC-ESI-MS/MS methods for the quantification of hydrazine mono lactose adduct and hydrazine di lactose adduct in isosorbide dinitrate and hydralazine hydrochloride tablets

Isosorbide dinitrate and hydralazine hydrochloride tablets treat heart failure in addition to conventional therapy, prolong hospitalization for heart failure, and enhance patient-reported functional status. LC-MS/MS methods developed and validated separately for the quantification of hydrazine mono-lactose adduct and hydrazine di-lactose adduct impurities in the isosorbide and hydralazine hydrochloride tablets. Separation of hydrazine mono-lactose adduct impurity achieved on ZIC-HILIC (100 × 4.6 mm, 5 µm) column with 0.1% formic acid in water as mobile phase A and acetonitrile as mobile phase B. The HPLC method gradient elution is; Tmin/% of B: 0/90, 15/40, 15.1/90, and 20/90. The flow rate is 1.0 mL per minute, and the injection volume is 20 µL. Separation of hydrazine di-lactose adduct impurity achieved on Inertsil HILIC (150 × 4.6 mm, 5 µm) column with 10 Mm ammonium acetate in water as mobile phase A and acetonitrile as mobile phase B. The HPLC method gradient elution is; Tmin/% of B: 0/90, 15/40, 15.1/90, and 18/90. The flow rate is 1.0 mL per minute, and the injection volume is 40 µL. Method validation has demonstrated both methods are specific, sensitive, linear, precise, accurate, stable and robust.

Authors

  • Muppavarapu, Venkatarao ;
  • Challa, Gangu Naidu ;
  • Gande, Mukteeshwar ;
  • Billa, Praveen Reddy ;
  • Yarraguntla, Srinivasa Rao
1 Citation0 Mentions13% FAIR0.6 Dataset Index
10.6084/m9.figshare.26318854.v1January 2024