Automated Author ProfileChalla, Gangu Naidu
Challa, Gangu Naidu
Current S-Index
Sum of Dataset Indices for all datasets
Average Dataset Index per Dataset
Average Dataset Index per dataset
Total Datasets
Total datasets for this author
Average FAIR Score
Average FAIR Score per dataset
Total Citations
Total citations to the author's datasets
Total Mentions
Total mentions of the author's datasets
S-Index Interpretation
The S-Index (Sharing Index) is a comprehensive metric that represents the cumulative impact of all your datasets. It is calculated as the sum of Dataset Index scores across all your claimed datasets.
What it means:
- A higher S-index indicates greater overall impact of your datasets relative to typical datasets in their fields of research
- The S-Index grows as you add more datasets or as existing datasets gain more citations and mentions
- It provides a single number to track your research data impact over time
Current S-Index: 1.3 (sum of 2 datasets Dataset Index scores)
More information here.
S-Index Over Time
Cumulative Citations Over Time
Cumulative Mentions Over Time
Datasets
Isosorbide dinitrate and hydralazine hydrochloride tablets treat heart failure in addition to conventional therapy, prolong hospitalization for heart failure, and enhance patient-reported functional status. LC-MS/MS methods developed and validated separately for the quantification of hydrazine mono-lactose adduct and hydrazine di-lactose adduct impurities in the isosorbide and hydralazine hydrochloride tablets. Separation of hydrazine mono-lactose adduct impurity achieved on ZIC-HILIC (100 × 4.6 mm, 5 µm) column with 0.1% formic acid in water as mobile phase A and acetonitrile as mobile phase B. The HPLC method gradient elution is; Tmin/% of B: 0/90, 15/40, 15.1/90, and 20/90. The flow rate is 1.0 mL per minute, and the injection volume is 20 µL. Separation of hydrazine di-lactose adduct impurity achieved on Inertsil HILIC (150 × 4.6 mm, 5 µm) column with 10 Mm ammonium acetate in water as mobile phase A and acetonitrile as mobile phase B. The HPLC method gradient elution is; Tmin/% of B: 0/90, 15/40, 15.1/90, and 18/90. The flow rate is 1.0 mL per minute, and the injection volume is 40 µL. Method validation has demonstrated both methods are specific, sensitive, linear, precise, accurate, stable and robust.
Authors
- Muppavarapu, Venkatarao ;
- Challa, Gangu Naidu ;
- Gande, Mukteeshwar ;
- Billa, Praveen Reddy ;
- Yarraguntla, Srinivasa Rao
Isosorbide dinitrate and hydralazine hydrochloride tablets treat heart failure in addition to conventional therapy, prolong hospitalization for heart failure, and enhance patient-reported functional status. LC-MS/MS methods developed and validated separately for the quantification of hydrazine mono-lactose adduct and hydrazine di-lactose adduct impurities in the isosorbide and hydralazine hydrochloride tablets. Separation of hydrazine mono-lactose adduct impurity achieved on ZIC-HILIC (100 × 4.6 mm, 5 µm) column with 0.1% formic acid in water as mobile phase A and acetonitrile as mobile phase B. The HPLC method gradient elution is; Tmin/% of B: 0/90, 15/40, 15.1/90, and 20/90. The flow rate is 1.0 mL per minute, and the injection volume is 20 µL. Separation of hydrazine di-lactose adduct impurity achieved on Inertsil HILIC (150 × 4.6 mm, 5 µm) column with 10 Mm ammonium acetate in water as mobile phase A and acetonitrile as mobile phase B. The HPLC method gradient elution is; Tmin/% of B: 0/90, 15/40, 15.1/90, and 18/90. The flow rate is 1.0 mL per minute, and the injection volume is 40 µL. Method validation has demonstrated both methods are specific, sensitive, linear, precise, accurate, stable and robust.
Authors
- Muppavarapu, Venkatarao ;
- Challa, Gangu Naidu ;
- Gande, Mukteeshwar ;
- Billa, Praveen Reddy ;
- Yarraguntla, Srinivasa Rao