Automated Author ProfileHeldens, Stijn
Heldens, Stijn
Current S-Index
Sum of Dataset Indices for all datasets
Average Dataset Index per Dataset
Average Dataset Index per dataset
Total Datasets
Total datasets for this author
Average FAIR Score
Average FAIR Score per dataset
Total Citations
Total citations to the author's datasets
Total Mentions
Total mentions of the author's datasets
S-Index Interpretation
The S-Index (Sharing Index) is a comprehensive metric that represents the cumulative impact of all your datasets. It is calculated as the sum of Dataset Index scores across all your claimed datasets.
What it means:
- A higher S-index indicates greater overall impact of your datasets relative to typical datasets in their fields of research
- The S-Index grows as you add more datasets or as existing datasets gain more citations and mentions
- It provides a single number to track your research data impact over time
Current S-Index: 3.2 (sum of 2 datasets Dataset Index scores)
More information here.
S-Index Over Time
Cumulative Citations Over Time
Cumulative Mentions Over Time
Datasets
Test data for the software demo of the manuscript 'Calibration-free estimation of field dependent aberrations for single molecule localization microscopy across large fields of view'. This dataset contains the first 800 frames from the 3D microtuble dataset from Figure 2 of the manuscript. It is a test dataset for the Software Demo accompanying the manuscript.
It concerns raw data for Single Molecule Localization Microscopy of microtubules of HeLa cells over a large 97 x 97 μm field of view. The images were acquired with 2 cylindrical lenses at the Fourier plane of the microscope to introduce astigmatism. The data was acquired in order to demonstrate the estimation of field dependent aberrations from single molecule localization.
Authors
- Droste, Isabel ;
- Schuitema, Erik ;
- Khan, Sajjad ;
- Heldens, Stijn ;
- van Werkhoven, Ben ;
- Lidke, Keith A. ;
- Stallinga, Sjoerd ;
- Rieger, Bernd
Test data for the software demo of the manuscript 'Calibration-free estimation of field dependent aberrations for single molecule localization microscopy across large fields of view'. This dataset contains the first 800 frames from the 3D microtuble dataset from Figure 2 of the manuscript. It is a test dataset for the Software Demo accompanying the manuscript.
It concerns raw data for Single Molecule Localization Microscopy of microtubules of HeLa cells over a large 97 x 97 μm field of view. The images were acquired with 2 cylindrical lenses at the Fourier plane of the microscope to introduce astigmatism. The data was acquired in order to demonstrate the estimation of field dependent aberrations from single molecule localization.
Authors
- Droste, Isabel ;
- Schuitema, Erik ;
- Khan, Sajjad ;
- Heldens, Stijn ;
- van Werkhoven, Ben ;
- Lidke, Keith A. ;
- Stallinga, Sjoerd ;
- Rieger, Bernd