Automated Author ProfileNicolas, Michael
Nicolas, Michael
Current S-Index
Sum of Dataset Indices for all datasets
Average Dataset Index per Dataset
Average Dataset Index per dataset
Total Datasets
Total datasets for this author
Average FAIR Score
Average FAIR Score per dataset
Total Citations
Total citations to the author's datasets
Total Mentions
Total mentions of the author's datasets
S-Index Interpretation
The S-Index (Sharing Index) is a comprehensive metric that represents the cumulative impact of all your datasets. It is calculated as the sum of Dataset Index scores across all your claimed datasets.
What it means:
- A higher S-index indicates greater overall impact of your datasets relative to typical datasets in their fields of research
- The S-Index grows as you add more datasets or as existing datasets gain more citations and mentions
- It provides a single number to track your research data impact over time
Current S-Index: 1.0 (sum of 2 datasets Dataset Index scores)
More information here.
S-Index Over Time
Cumulative Citations Over Time
Cumulative Mentions Over Time
Datasets
Purpose: To compare the stromal bed surface quality and the accuracy of dissection depth after deep lamellar cuts using the Leonardo Da Vinci (LDV) femtosecond laser (Z6) and the ONE Microkeratome. Methods: Deep lamellar cuts were performed on nine human donor corneoscleral buttons: five with the LDV femtosecond (FS) laser (Z6) (Ziemer) and four with the ONE Microkeratome (MK) (Moria). Corneal thickness was measured with ultrasound pachymetry before and after the dissection. The Stromal bed quality was evaluated using light microscopy (n = 4) and scanning electron microscopy (SEM) (n = 9). The surface roughness on SEM images was graded on the scale of 1 (smoothest) to 5 (roughest) by four observers, blinded to the method used. Particle analysis on the SEM images was performed in order to have an objective measure of smoothness. Results: The achieved dissection depth using the FS laser was 496.4 ± 46.4 µm when attempting 500 µm and 474 ± 60 µm with the microkeratome when attempting 350 µm. Histological evaluation of the corneoscleral buttons by both light and electron microscopy showed significantly smoother surface using the FS laser compared to the microkeratome. There were fewer and smaller particles observed in the SEM images of FS laser cut buttons (p < 0.001).The average observer based score of anterior surface roughness (50×) was 2.2 for the FS laser and 3.9 for the microkeratome dissections (p < 0.001). Conclusions: The LDV femtosecond laser (Z6) platform is capable of creating deep corneal lamellar dissection with smoother surface quality and with more predictable cut depth as compared to the One Microkeratome.
Authors
- Varga, Zsolt ;
- Bergin, Ciara ;
- Roy, Sylvain ;
- Nicolas, Michael ;
- Tschuor, Patrizia ;
- Majo, François
Purpose: To compare the stromal bed surface quality and the accuracy of dissection depth after deep lamellar cuts using the Leonardo Da Vinci (LDV) femtosecond laser (Z6) and the ONE Microkeratome. Methods: Deep lamellar cuts were performed on nine human donor corneoscleral buttons: five with the LDV femtosecond (FS) laser (Z6) (Ziemer) and four with the ONE Microkeratome (MK) (Moria). Corneal thickness was measured with ultrasound pachymetry before and after the dissection. The Stromal bed quality was evaluated using light microscopy (n = 4) and scanning electron microscopy (SEM) (n = 9). The surface roughness on SEM images was graded on the scale of 1 (smoothest) to 5 (roughest) by four observers, blinded to the method used. Particle analysis on the SEM images was performed in order to have an objective measure of smoothness. Results: The achieved dissection depth using the FS laser was 496.4 ± 46.4 µm when attempting 500 µm and 474 ± 60 µm with the microkeratome when attempting 350 µm. Histological evaluation of the corneoscleral buttons by both light and electron microscopy showed significantly smoother surface using the FS laser compared to the microkeratome. There were fewer and smaller particles observed in the SEM images of FS laser cut buttons (p < 0.001).The average observer based score of anterior surface roughness (50×) was 2.2 for the FS laser and 3.9 for the microkeratome dissections (p < 0.001). Conclusions: The LDV femtosecond laser (Z6) platform is capable of creating deep corneal lamellar dissection with smoother surface quality and with more predictable cut depth as compared to the One Microkeratome.
Authors
- Varga, Zsolt ;
- Bergin, Ciara ;
- Roy, Sylvain ;
- Nicolas, Michael ;
- Tschuor, Patrizia ;
- Majo, François