Site is currently under maintenance
Some features may be unavailable or limited during this time. We apologize for any inconvenience and appreciate your patience.

Published on 01 January 2023

Geochemical data collected in river water and shallow groundwater in a subarctic region (Matane river, QC, Canada)

View Dataset
Biehler, Antoine;Buffin-Bélanger, Thomas;Baudron, Paul;Chaillou, Gwénaëlle

Description

This study aims to quantify groundwater discharges and associated DIC and CO2 fluxes at a high- and low- resolution scales on the Matane River (Qc, Canada). The flux calculations were based on a dataset including radon-222 activities (i.e., 222Rn), and measurements of dissolved inorganic carbon (i.e., DIC), total alkalinity, CO2 partial pressure (i.e., PCO2), and pH. The low-resolution study was undertaken at the corridor scale (07/2017), while the high-resolution study focused on a ~800 m long meander reach (08/2017). At the corridor scale, for the 12 sampling points, river water was analyzed in a riffle and in a pool to better represent river sections. Groundwater was also sampled from 4 private wells and in 2 piezometers for the corridor scale study, and from 12 piezometers inserted into the 18 ha meander floodplain for the meander scale study.

Citations (0)

Mentions (0)

Metrics

Dataset Index

0.5

FAIR Score

96%

Citations

0

Mentions

0

Metrics Over Time

Publication Details

DOI

Publisher

PANGAEA

Assigned Domain

Subfield

Geochemistry and Petrology

Field

Earth and Planetary Sciences

Domain

Physical Sciences

Confidence Score

53%

Source

Scholar Data Model

Keywords

aquifer-river connectivityCarbonate chemistryinorganic carbonradonsubarctic river systemSample IDSiteDATE/TIMELATITUDELONGITUDETypeLocationELEVATIONRadon-222Radon-222, standard deviationTemperature, waterConductivity, electricalpHCarbon, inorganic, dissolvedCarbon, inorganic, dissolved, standard deviationAlkalinity, totalAlkalinity, total, standard deviationCarbon dioxide, partial pressureMethod commentPiezometerWGS84 EPSG:4326Automated level loggers (Hobo U20-001) combined with DGPS elevation (only for piezometers)Two RAD7 Alpha spectrometer (Durridge Inc.) in a series with an outgassing unitMultiparametric probe (600QS, YSI Inc.)Multiparametric probe, YSI Inc., 600QS [calibrated with 1413µS/cm standard]NBS values, Multiparametric probe (600QS, YSI Inc.) calibrated with three NBS buffers with known pH values (4.00, 7.00, and 10.00)Flow injection analysis technique based on the method proposed by Hall and Aller, (1992) and calibrated with a reagent grade sodium bicarbonate (NaHCO3) solution, 2 replicates by samplesGRAN titration on 50 mL water samples with a Metrohm 848 Titrino Plus device calibrated by comparison with a Dickson certified reference material, 3 replicates by samplesmeasured or calculated according to the "PCO2 method" column"in-situ" refers to in situ measurments using a showerhead-type gas exchanger connected to a PCO2 logger (CM-0001, CO2Meter, Inc)

Normalization Factors

FT

65.38

CTw

1.00

MTw

1.00