Data set of a thermal response test on a planar trench collector

Van de Ven, Adinda;Neth, Fabian;Köhler, Andreas;Buchmiller, Daniel;Volkmer, Stephan;Koenigsdorff, Roland;Albers, Anna;Steger, Hagen;Schindler, Linda;Zorn, Roman

Description

This data set provides three different temperature measurements (PT100, fiber optic measurement, thermistors), as well as the determination of the volumetric water content and the bulk electrical conductivity of the subsurface. During the published period, a thermal response test was carried out. On April 28th, at 15:25, the fluid circulation began, and heat injection started at 15:38 on April 28th and continued until May 3rd. The test was conducted with a constant volume flow of 1.00 m³/h and a constant heat injection rate of 0.88 kW.

Citations (0)

Mentions (0)

Metrics

Dataset Index

0.9

FAIR Score

85%

Citations

1

Mentions

0

Metrics Over Time

Publication Details

DOI

Publisher

Zenodo

License

Creative Commons Attribution 4.0 International

Assigned Domain

Subfield

Computational Mechanics

Field

Engineering

Domain

Physical Sciences

Confidence Score

51%

Source

Scholar Data Model

Keywords

shallow geothermal systemsgeothermal ground heat exchangertrench collectortemperature measurementmoisture measurementthermal response test

Normalization Factors

FT

57.69

CTw

1.00

MTw

1.00