Snake River Plain Geothermal Play Fairway Analysis Project MT Data
View DatasetDescription
MT is measured in the field by using induction coils to measure the time-varying magnetic source for frequencies between 1000-0.001Hz, and electric dipoles to measure the Earth's electrical response. Because the magnetic source field is polarized, orthogonal directions of the fields need to be measured to get a complete description of the fields. In all measurements collected for this project, induction coils and electric dipoles were aligned with geomagnetic north and east. MT data were collected at 22 stations with a ZEN 32-bit data logger developed by Zonge International, magnetic fields were measured with ANT-4 induction coils, and electric fields where measured with Ag-AgCl reference electrodes from Borin on 50m dipoles. The data was collected on a repeating schedule of 10min at 4096samples/s and 7 hours and 50 minutes at 256 samples/s over a 20-24 hour period. To convert time series data into the frequency domain and get estimations of the impedance tensor, the processing code BIRRP was used (Chave & Thompson 2004). Simultaneous measurements were used as remote references to reduce noise and bias in the data. Chave, A. D., & Thomson, D. J. 2004. Bounded inuence magnetotelluric response function estimation. Geophys. J. Int., 157, 988-1006.
Citations (0)
No citations found
Mentions (0)
No mentions found
Metrics Over Time
Publication Details
Subfield
Oceanography
Field
Earth and Planetary Sciences
Domain
Physical Sciences
Confidence Score
61%
Source
Scholar Data Model