Automated Author ProfileTerzoudi, Georgia
Terzoudi, Georgia
Current S-Index
Sum of Dataset Indices for all datasets
Average Dataset Index per Dataset
Average Dataset Index per dataset
Total Datasets
Total datasets for this author
Average FAIR Score
Average FAIR Score per dataset
Total Citations
Total citations to the author's datasets
Total Mentions
Total mentions of the author's datasets
S-Index Interpretation
The S-Index (Sharing Index) is a comprehensive metric that represents the cumulative impact of all your datasets. It is calculated as the sum of Dataset Index scores across all your claimed datasets.
What it means:
- A higher S-index indicates greater overall impact of your datasets relative to typical datasets in their fields of research
- The S-Index grows as you add more datasets or as existing datasets gain more citations and mentions
- It provides a single number to track your research data impact over time
Current S-Index: 3.5 (sum of 5 datasets Dataset Index scores)
More information here.
S-Index Over Time
Cumulative Citations Over Time
Cumulative Mentions Over Time
Datasets
Depending on the exposure scenario, different biological and/or physical assays will be required to recover the exposure situation and to obtain reliable dose estimates to aid medical decision making. Inter-laboratory comparisons (ILCs) are a central tool to validate and improve the performance of methods and laboratories. In most cases such ILCs are performed under laboratory conditions where the influence of parameters contributing to uncertainties can be minimized. In a real-life scenario, the situation is much more complicated, and it is therefore crucial to validate methods and laboratories’ abilities to carry out these methods under more realistic conditions. In 2019, EURADOS (The European Radiation Dosimetry Group) Working Group 10 (Retrospective Dosimetry) and RENEB (Running the European Network of Biological and retrospective Physical dosimetry) organized a field exercise in Lund, Sweden, to validate different methods for biological and physical retrospective dosimetry in parallel by simulating real-life exposure scenarios. For the dicentric chromosome assay (DCA), 18 blood tubes were distributed across 8 thermos flasks filled with heated water and positioned at the hips and shoulders of anthropomorphic phantoms in different geometries. Two irradiations were performed with a 1.36 TBq 192Ir-source, each with two phantoms, to simulate close, distant, lateral or partially shielded exposures. For each of the blood tubes DCA dose estimates were provided by at least one laboratory and for tubes from four thermos flasks by 17 participating RENEB laboratories. In addition, blood from the different thermos flasks on each phantom was mixed to simulate heterogeneous exposures. Three radio-photoluminescence (RPL) glass dosimeters (GD) were placed at each tube to assess reference doses and the inter- and intra-tube variability. The results from the DCA were homogeneous between participants and matched well with RPL GD reference doses (≥95% of estimates within ±0.5 Gy of the reference). For samples close to the source, exposed to doses >1 Gy, systematic underestimation could be corrected by accounting for exposure time. Heterogeneity within and between tubes was detected for RPL GD reference doses as well as for doses estimates from the DCA. The sample simulating a heterogeneous exposure with two different doses was detected by ∼50% of the participants. The participants were able to successfully estimate the doses and to provide important information on the exposure scenarios under conditions closely resembling a real-life situation. The reliability of the results emphasizes the value of the DCA for retrospective dosimetry under field conditions.
Authors
- Endesfelder, David ;
- Oestreicher, Ursula ;
- Kulka, Ulrike ;
- Ainsbury, Elizabeth A. ;
- Moquet, Jayne ;
- Barnard, Stephen ;
- Gregoire, Eric ;
- Martinez, Juan S. ;
- Trompier, François ;
- Ristic, Yoann ;
- Woda, Clemens ;
- Waldner, Lovisa ;
- Beinke, Christina ;
- Vral, Anne ;
- Barquinero, Joan-Francesc ;
- Hernandez, Alfredo ;
- Sommer, Sylwester ;
- Lumniczky, Katalin ;
- Hargitai, Rita ;
- Montoro, Alegría ;
- Milic, Mirta ;
- Gil, Octávia Monteiro ;
- Valente, Marco ;
- Bobyk, Laure ;
- Sevriukova, Olga ;
- Sabatier, Laure ;
- Prieto, María Jesús ;
- Domene, Mercedes Moreno ;
- Testa, Antonella ;
- Patrono, Clarice ;
- Terzoudi, Georgia ;
- Triantopoulou, Sotiria ;
- Histova, Rositsa ;
- Wojcik, Andrzej
Biological and/or physical assays for retrospective dosimetry are valuable tools to recover the exposure situation and to aid medical decision making. To further validate and improve such biological and physical assays, in 2019, EURADOS Working Group 10 and RENEB performed a field exercise in Lund, Sweden, to simulate various real-life exposure scenarios. For the dicentric chromosome assay (DCA), blood tubes were located at anthropomorphic phantoms positioned in different geometries and were irradiated with a 1.36 TBq 192Ir-source. For each exposure condition, dose estimates were provided by at least one laboratory and for four conditions by 17 participating RENEB laboratories. Three radio-photoluminescence glass dosimeters were placed at each tube to assess reference doses. The DCA results were homogeneous between participants and matched well with the reference doses (≥95% of estimates within ±0.5 Gy of the reference). For samples close to the source systematic underestimation could be corrected by accounting for exposure time. Heterogeneity within and between tubes was detected for reference doses as well as for DCA doses estimates. The participants were able to successfully estimate the doses and to provide important information on the exposure scenarios under conditions closely resembling a real-life situation.
Authors
- Endesfelder, David ;
- Oestreicher, Ursula ;
- Kulka, Ulrike ;
- Ainsbury, Elizabeth A. ;
- Moquet, Jayne ;
- Barnard, Stephen ;
- Gregoire, Eric ;
- Martinez, Juan S. ;
- Trompier, François ;
- Ristic, Yoann ;
- Woda, Clemens ;
- Waldner, Lovisa ;
- Beinke, Christina ;
- Vral, Anne ;
- Barquinero, Joan-Francesc ;
- Hernandez, Alfredo ;
- Sommer, Sylwester ;
- Lumniczky, Katalin ;
- Hargitai, Rita ;
- Montoro, Alegría ;
- Milic, Mirta ;
- Gil, Octávia Monteiro ;
- Valente, Marco ;
- Bobyk, Laure ;
- Sevriukova, Olga ;
- Sabatier, Laure ;
- Prieto, María Jesús ;
- Domene, Mercedes Moreno ;
- Testa, Antonella ;
- Patrono, Clarice ;
- Terzoudi, Georgia ;
- Triantopoulou, Sotiria ;
- Histova, Rositsa ;
- Wojcik, Andrzej
Biological and/or physical assays for retrospective dosimetry are valuable tools to recover the exposure situation and to aid medical decision making. To further validate and improve such biological and physical assays, in 2019, EURADOS Working Group 10 and RENEB performed a field exercise in Lund, Sweden, to simulate various real-life exposure scenarios. For the dicentric chromosome assay (DCA), blood tubes were located at anthropomorphic phantoms positioned in different geometries and were irradiated with a 1.36 TBq 192Ir-source. For each exposure condition, dose estimates were provided by at least one laboratory and for four conditions by 17 participating RENEB laboratories. Three radio-photoluminescence glass dosimeters were placed at each tube to assess reference doses. The DCA results were homogeneous between participants and matched well with the reference doses (≥95% of estimates within ±0.5 Gy of the reference). For samples close to the source systematic underestimation could be corrected by accounting for exposure time. Heterogeneity within and between tubes was detected for reference doses as well as for DCA doses estimates. The participants were able to successfully estimate the doses and to provide important information on the exposure scenarios under conditions closely resembling a real-life situation.
Authors
- Endesfelder, David ;
- Oestreicher, Ursula ;
- Kulka, Ulrike ;
- Ainsbury, Elizabeth A. ;
- Moquet, Jayne ;
- Barnard, Stephen ;
- Gregoire, Eric ;
- Martinez, Juan S. ;
- Trompier, François ;
- Ristic, Yoann ;
- Woda, Clemens ;
- Waldner, Lovisa ;
- Beinke, Christina ;
- Vral, Anne ;
- Barquinero, Joan-Francesc ;
- Hernandez, Alfredo ;
- Sommer, Sylwester ;
- Lumniczky, Katalin ;
- Hargitai, Rita ;
- Montoro, Alegría ;
- Milic, Mirta ;
- Gil, Octávia Monteiro ;
- Valente, Marco ;
- Bobyk, Laure ;
- Sevriukova, Olga ;
- Sabatier, Laure ;
- Prieto, María Jesús ;
- Domene, Mercedes Moreno ;
- Testa, Antonella ;
- Patrono, Clarice ;
- Terzoudi, Georgia ;
- Triantopoulou, Sotiria ;
- Histova, Rositsa ;
- Wojcik, Andrzej
Purpose: To establish a training data set of digital images and to investigate the scoring criteria and dose assessment of the dicentric assay within the European network of biodosimetry (RENEB), a web based scoring inter-comparison was undertaken by 17 RENEB partners. Materials and methods: Two sets of 50 high resolution images were uploaded onto the RENEB website. One set included metaphases after a moderate exposure (1.3 Gy) and the other set consisted of metaphases after a high dose exposure (3.5 Gy). The laboratories used their own calibration curves for estimating doses based on observed aberration frequencies. Results: The dose estimations and 95% confidence limits were compared to the actual doses and the corresponding z-values were satisfactory for the majority; only the dose estimations from two laboratories were too low or too high. The coefficients of variation were 17.6% for the moderate and 11.2% for the high dose. Metaphases with controversial results could be identified for training purposes. Conclusions: Overall, the web based scoring of the two galleries by the 17 laboratories produced very good results. Application of web based scoring for the dicentric assay may therefore be a relevant strategy for an operational biodosimetry assistance network.
Authors
- Romm, Horst ;
- Ainsbury, Elizabeth A. ;
- Barquinero, Joan Francesc ;
- Barrios, Leonardo ;
- Beinke, Christina ;
- Cucu, Alexandra ;
- Domene, Mercedes Moreno ;
- Filippi, Silvia ;
- Gil, Octávia Monteiro ;
- Gregoire, Eric ;
- Hadjidekova, Valeria ;
- Vasia Hatzi ;
- Lindholm, Carita ;
- Radhia M´ Kacher ;
- Montoro, Alegria ;
- Moquet, Jayne ;
- Noditi, Mihaela ;
- Oestreicher, Ursula ;
- Palitti, Fabrizio ;
- Pantelias, Gabriel ;
- Prieto, María Jesús ;
- Popescu, Irina ;
- Rothkamm, Kai ;
- Sebastià, Natividad ;
- Sommer, Sylwester ;
- Terzoudi, Georgia ;
- Testa, Antonella ;
- Wojcik, Andrzej
Purpose: To establish a training data set of digital images and to investigate the scoring criteria and dose assessment of the dicentric assay within the European network of biodosimetry (RENEB), a web based scoring inter-comparison was undertaken by 17 RENEB partners. Materials and methods: Two sets of 50 high resolution images were uploaded onto the RENEB website. One set included metaphases after a moderate exposure (1.3 Gy) and the other set consisted of metaphases after a high dose exposure (3.5 Gy). The laboratories used their own calibration curves for estimating doses based on observed aberration frequencies. Results: The dose estimations and 95% confidence limits were compared to the actual doses and the corresponding z-values were satisfactory for the majority; only the dose estimations from two laboratories were too low or too high. The coefficients of variation were 17.6% for the moderate and 11.2% for the high dose. Metaphases with controversial results could be identified for training purposes. Conclusions: Overall, the web based scoring of the two galleries by the 17 laboratories produced very good results. Application of web based scoring for the dicentric assay may therefore be a relevant strategy for an operational biodosimetry assistance network.
Authors
- Romm, Horst ;
- Ainsbury, Elizabeth A. ;
- Barquinero, Joan Francesc ;
- Barrios, Leonardo ;
- Beinke, Christina ;
- Cucu, Alexandra ;
- Domene, Mercedes Moreno ;
- Filippi, Silvia ;
- Gil, Octávia Monteiro ;
- Gregoire, Eric ;
- Hadjidekova, Valeria ;
- Vasia Hatzi ;
- Lindholm, Carita ;
- Radhia M´ Kacher ;
- Montoro, Alegria ;
- Moquet, Jayne ;
- Noditi, Mihaela ;
- Oestreicher, Ursula ;
- Palitti, Fabrizio ;
- Pantelias, Gabriel ;
- Prieto, María Jesús ;
- Popescu, Irina ;
- Rothkamm, Kai ;
- Sebastià, Natividad ;
- Sommer, Sylwester ;
- Terzoudi, Georgia ;
- Testa, Antonella ;
- Wojcik, Andrzej